BIO RAD 400-0174 Instrucciones de operaciones Pagina 87

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 485
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 86
Cabin
87
Pos: 9.37.14 /B etriebsanleitung/ Kabine/Klimaanl age/Heizung/A nzeige von Störu ngen im Dis play @ 0\mod _1195734281 959_78.doc @ 2 605
5.16.9 Showing Faults in the Display
Error code (F0)´
Fig. 70:
Error in room temperature sensor is indicated by flashing indicator (F0).
Note
The control unit has recorded an error in the room temperature sensor.
Controller is no longer ready for operation.
Cause of sensor fault:
Short circuit or interruption in sensor line, plug connection on the sensor or control unit ,
temperature sensor defective. The controller will not be ready for operation again until the error
is eliminated. Then the sensor fault no longer appears.
Note
If a sensor fault occurs, the controller continues working with the setting that
was valid before the fault was recorded.
Vista de pagina 86
1 2 ... 82 83 84 85 86 87 88 89 90 91 92 ... 484 485

Comentarios a estos manuales

Sin comentarios