Error Messages
Message Meaning Possible cause
SmartDrive
Limp modeCheck Remedy
Short circuit/broken cable in the wiring
for actuator valve 1 pump 1
Check wiring to actuator valve 1
for pump 1
Valve plug defective Replace valve plug
Coil for solenoid valves defective Replace coil
Internal SmartDrive error Replace SmartDrive
Short circuit/broken cable in the wiring
for actuator valve 2 pump 1
Check wiring to actuator valve 2
for pump 1
Valve plug defective Replace valve plug
Coil for solenoid valves defective Replace coil
Internal SmartDrive error Replace SmartDrive
60 SmartDrive
current pump 1
coil 1 (Y2)
Error: Actuator valve 1
drive pump 1 – front
axle forward
61 SmartDrive
current pump 1
coil 2 (Y1)
Error: Actuator valve 2
dri
ve pump 1 – front
axle backward
Short circuit/broken cable in the wiring
for stop valve pump 1
Check wiring to stop valve
for pump 1
Valve plug defective Replace valve plug
Coil for solenoid valve defective Replace coil
Internal SmartDrive error Replace SmartDrive
Short circuit/broken cable in the wiring
for actuator valve 1 pump 2
Check wiring to actuator valve 1
for pump 2
Valve plug defective Replace valve plug
Coil for solenoid valves defective Replace coil
Internal SmartDrive error Replace SmartDrive
SmartDrive wiring
pump 1 coil 3
Error: Stop valve drive
pump 1 – front axle
63 SmartDrive
Current pump 2
coil 1 (Y4)
Error: Actuator valve 1
drive pump 2 – rear axle
forward
62