BIO RAD 400-0174 Instrucciones de operaciones Pagina 416

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 485
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 415
Error Messages
Message Meaning Possible cause
SmartDrive
Limp modeCheck Remedy
Hydraulic oil too hot Allow the machine to cool down
Radiator dirty Clean the radiator
Run travelling gear diagnostics
Short circuit/broken cable in wiring for
the temperature sensor flush valve
Check the wiring for the temperature
sensor flush valve
Flush valve temperature sensor
defective
Replace the temperature sensor flush
valve
Internal SmartDrive error Replace SmartDrive
Release travelling gear switch is
not actuated
Switch on the travelling gear switch
44 SmartDrive oil
temperature too
high (B5)
Error: Oil temperature
too high
45 Release travelling
gear switch not
actuated
(S3)
Error: Attempt to move
without
release travelling gear
Perform operating panel diagnostics
Short circuit/broken cable in the wiring
of the switch
Check the wiring to the release travelling
gear switch
Release travelling gear switch
defective
Replace release travelling gear switch
Internal SmartDrive error Replace SmartDrive
actuated
(S3)
release travelling gear
Vista de pagina 415