Error Messages
Perform joystick diagnostics
Power supply voltage
joystick too low
Check fuse -22-F57
Ch
eck fuse -22-F65
Power supply voltage
central electrical system defective
LED -22-LD63 not lit Check fuse -22-F63
Check fuse -22-F92
Wiring defective Check wiring
Battery dead Charge battery, check battery acid,
replace battery
Joystick
Message Meaning P
ossible cause Check Remedy
113 Joystick
undervoltage 12V
Error: 12 Volt
power supply voltage
too low
Charge indicator lamp defective Check charge indicator lamp,
Check wiring
Dynamo defective Replace the dynamo
Internal joystick error Replace joystick
Perform joystick diagnostics
The controller of the dynamo is
defective
Replace the dynamo
Dynamo defective Replace the dynamo
Battery change-over relay defective Replace battery change-over relay
Internal joystick error Replace joystick
114 Joystick
overvoltage 12V
Error: 12 Volt
power supply voltage
too high