Error Messages
Possible cause Check Remedy
KMC1
Message Meaning
Run electronics diagnostics
KMC1 LD27 not lit
Short circuit in the wiring
to a digital sensor
Check wiring
Digital sensor defective Check the sensors and replace, if and
when necessary
Charge indicator lamp defective Check the charge indicator lamp, check
the wiring
Dynamo defective
Check the excitation voltage, check the
1108 KMC1 voltage 8V
dig.sensors
Error: 8 V voltage of
digital sensors
Dynamo defective
Check the excitation voltage, check the
wiring, replace the dynamo
Battery dead Charge battery, check battery acid,
replace battery
Internal error - KMC1 Replace KMC1